12heads Ultrasonic Mist Maker Fogger Water Fountain Pond Atomizer
Product Usage:
For humidifying machine, fog equipment movement, or directly used as a humidifier (to be connected to 48V DC). Use matters needing attention:
1 when the atomizer is working correctly, please don't put their hands on the above atomizer spray chamber, to prevent ultrasonic injury.
2. The atomizer must be in the water to work properly, before use, please the into the water and then connect the power, and to ensure that the fogging piece surface in the water, so as not to damage the atomizer.
3. when to stop using the atomizer before you disconnect the power supply, and then removed from the water atomizer.
4. use the atomizer, please use the output power is more than 250W, the output voltage is DC45 + 5V power supply.
5. when a plurality of atomizers set in the same container when in use, respectively is equipped with a separate power supply, not with a single power supply connection multiple atomizers use, and pay attention to the shell of the atomizer communicated each other, to thereby generate electrical corrosion.
6. Atomizer fog must use fan forced discharge, planar space and each nebulizer retained 350CM2, so as to avoid water temperature too high shorten the lifespan of the atomizer.
7.The atomizer is not suitable for the atomization of corrosive liquid, so as to avoid damage to the metal shell and atomizer atomizing sheet.
8. the installation process please don't damage the water level sensing switch, water level switch to avoid failures caused by uncontrolled atomizer.
The water level switch is damaged should be stopped, otherwise there will be a piece of dry burning so as to further damage the atomizing atomizer. At this time need to be repaired by professional maintenance personnel to use. Product warranty:
1 the product warranty period is one year. Normal use within a year if the failure can be returned to the original factory warranty, non normal use of the failure, can be carried out with a taste warranty, depending on the circumstances.
2 the following circumstances, does not belong to the scope of our quality assurance. According to the contents of the store - installation use and maintenance of the fault. The product is without dismantling repair, modification or additional parts. The loss (such as atomization etc.) is not within the scope of warranty.
Remarks:
1.The atomizing capacity is related to the power supply voltage, power supply current, water temperature, water quality, water level and air flow. The fog size is based on test data obtained from our standard test environment.
2.Water level is the vertical distance from the surface of the shell to the surface of the water.
3.The atomizer with working voltage working current will be increased slightly, slightly with increasing temperature.
4.Water quality will affect the identification of water shortage protective switches, and recommend the use of clean tap water.
5.Generally, the conductivity of clean tap water is 120-250 US/CM, the conductivity of pure water is 5-15US/CM, and the specific conductivity is determined by the local water quality.
6.Pay attention to the water quality can not be corrosive, easy to rot the shell; water can not contain alkaline, oily substances, will reduce the amount of fog products.
7.The product cannot be connected to the ground when it is installed (because the product shell itself has positive electricity)
Product Image
Product model description
(1)Atomizer case (304 stainless steel)
(2) Fixed hole
(3)Power positive lead
(4)Negative lead
(5)Water level induction switch
(6)Power indicator
(7)ultrasonic atomizer
(8)Metal press ring
(9)Seal ring
Product features
1.The water quality of the atomization is more adaptable, and the same atomizer can work normally with pure water or tap water.
2. The utility model has wide application range, and ensures that the product can be used normally under the condition of large change of the city electricity.
3. A polarity protection circuit is provided to prevent the user from damaging the product on the contrary.
4. A polarity protection circuit is provided to prevent the user from damaging the product on the contrary.
5. The circuit of a single nozzle is designed independently, and the over-current protection circuit is adopted to avoid the burning of the circuit of a certain nozzle and damage the power supply, and the normal operation of other nozzles can not be affected.
6. The current voltage and temperature is less affected, because the current in each nozzle by electronic automatic adjustment, the current will decrease with the increase of temperature (does not affect the quantity of fog, to avoid the power tube), the current increases caused by severe fever and damage the vicious spiral atomizer.
7. This product uses high thermal conductivity, corrosion resistance, and mechanical strength of the metal shell, reducing the temperature difference between the host and the water, thereby prolonging the service life of the product.
TYPE |
OKS-WH150W |
OKS-WH180W |
OKS-WH250W |
OKS-WH300W |
OKS-WH350W |
Rated Power |
150W |
180W |
250W |
300W |
350W |
Operating Voltage |
DC36V |
DC48V |
DC48V |
DC48V |
DC48V |
Working current |
4A |
3.5A |
5A |
6.3A |
5.5A |
Stand-by current |
0.02A |
0.02A |
0.02A |
0.02A |
0.02A |
Atomization |
2000ML/H |
2500ML/H |
4500ML/H |
5500ML/H |
5000ML/H |
Working water temperature |
5-50°C |
5-50°C |
5-50°C |
5-50°C |
5-50°C |
Best water level |
7-9CM |
7-9CM |
7-9CM |
7-9CM |
7-9CM |
Turn on the water level |
5.5CM |
5.5CM |
5.5CM |
5.5CM |
5.5CM |
Turn off the water level
|
<5.5CM |
<5.5CM |
<5.5CM |
<5.5CM |
<5.5CM |
Temperature control |
55°C |
55°C |
55°C |
55°C |
55°C |
Temperature control recovery |
40°C |
40°C |
40°C |
40°C |
40°C |
Size of atomizing:φ20 frequency:1.7MHZ material:Glass glaze |
Remarks:
1.The atomizing capacity is related to the power supply voltage, power supply current, water temperature, water quality, water level and air flow. The fog size is based on test data obtained from our standard test environment.
2.Water level is the vertical distance from the surface of the shell to the surface of the water.
3.The atomizer with working voltage working current will be increased slightly, slightly with increasing temperature
4.Water quality will affect the identification of water shortage protective switches, and recommend the use of clean tap water.
5.Generally, the conductivity of clean tap water is 120-250 US/CM, the conductivity of pure water is 5-15US/CM, and the specific conductivity is determined by the local water quality.
6.Pay attention to the water quality can not be corrosive, easy to rot the shell; water can not contain alkaline, oily substances, will reduce the amount of fog products.
7.The product cannot be connected to the ground when it is installed (because the product shell itself has positive electricity)
Product maintenance and maintenance
After the atomizer is worked for a long time, the surface of the shell and the atomizing sheet can be deposited with scale, and the service life and the atomizing quantity are seriously affected, so it is recommended that the atomizer be cleaned at least once every half a month. When cleaning, can be dipped in alcohol soft cloth gently scrub atomizer shell and atomizing surface, do not use hard objects to clean atomized tablets, so as not to scratch the fog.
Quality will affect the service life of atomizer, it is recommended to use clean water.
After the atomizer after working for a long time (about 5000 hours), atomization life attenuation, atomization quantity will decrease, then you can replace the atomizing piece new, atomizing sheet and supporting tool key please contact your local dealer or the company to buy. The method of replacement can be referred to (Figure 1), and the procedures of replacement are as follows:
Cut off the power supply, remove the atomizer from the water, upside down and stay for a while, the atomizer of water flow out after all, and then dry cloth to wipe the spray cavity and the inner surface of the water atomizer.
Unscrew the press ring with the tool key, remove the old energy change plate, and keep the atomizing energy exchange. The cavity is clean and dry.
The new energy transfer plate faces up, and the reverse side is fitted and tightened.
Common troubleshooting
Fault phenomenon |
Reason analysis |
Processing method |
atomizer is out of power and the indicator light is not on the shell
|
electricity is not working. |
Check that the power plug is plugged in and the power is damaged |
The power of the atomizer is polarity reversed |
Switch the polarity of the power in |
The power supply of the atomizer is normal and the indicator light is on, but not spray
|
The water level in the container of the atomizer is too low to reach its normal working water level |
Add enough water |
atomizer in the atomizer does not spray |
The damage or bad contact of the atomizing piece |
The line of a nozzle in the main machine is damaged
|
Replace the new atomizing film |
Return dealer or business warranty |
One or more nozzles in the atomizer appear less foggy |
Atomizing film aging or damage |
Replace the new atomizing film |
shell of atomizer and the coating on the surface of atomizing piece are easy to fall off
|
Atomized corrosive liquid |
Many products are used in the same container, but the casing is not connected |
Should not be atomized corrosive liquid, it is recommended to replace |
The enclosure of each product is communicated with each other |
12heads Ultrasonic Mist Maker Fogger Water Fountain Pond Atomizer