• 6 Head Fogger Maker Ultrasonic Mist Humidifier
  • 6 Head Fogger Maker Ultrasonic Mist Humidifier
  • 6 Head Fogger Maker Ultrasonic Mist Humidifier
  • 6 Head Fogger Maker Ultrasonic Mist Humidifier
  • 6 Head Fogger Maker Ultrasonic Mist Humidifier
  • 6 Head Fogger Maker Ultrasonic Mist Humidifier

6 Head Fogger Maker Ultrasonic Mist Humidifier

Usage: Ulrasonic
Purpose: Gas Manufacturing
Parts: Transformers
Application Fields: Medical
Noise Level: Low
Machine Size: Small
Gold Member Since 2020

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
6 Head
Condition
New
Certification
RoHS, ISO
Power
50-380W
Frequency
1.7MHz
Transport Package
Cartoon
Specification
1 head -10 head
Trademark
OKS
Origin
China
HS Code
8543909000
Production Capacity
10000/Month

Product Description

Ultrasonic atomizer
The ultrasonic atomizer uses electronic high-frequency oscillation (the
oscillation frequency is 1.7mhz, which exceeds the range of human
hearing, and the electronic oscillation is not harmful to humans and
animals) through the high-frequency resonance of the ceramic atomizing
sheet to disperse the liquid water molecular structure. It produces a
natural and elegant water mist without heating and adding any chemical
reagents. Compared with the heating atomization method, energy is
saved by 90%. In addition, a large amount of negative ions will be
released during the atomization process, which reacts electrostatically
with the smoke and dust floating in the air to make them precipitate and
effectively remove formaldehyde. , Carbon monoxide, bacteria and other
harmful substances, to purify the air and reduce the occurrence of
diseases.
Liquid that can be atomized:
Tap water, purified water, soft water, electrolyzed water, distilled water
and neutral water with a pH value of 5-8. The water temperature is
required to be between 10-50 degrees.
Liquid that cannot be atomized:
Alcohol, washing water, sulfuric acid, sea water, oily, viscous (such asyogurt, soy milk, etc.) acid-base salt liquids, alkaline water has low
surface tension and cannot be atomized; acidity and salinity will cause
corrosion and should not be used.
Control method of atomization water level:
1. It is directly installed in a sink with a water depth of 7-9CM, suitable
for occasions where the water level is stable or artificial water is added.
2. Applying buoys to maintain the water level is suitable for occasions
where the water level depth is deep or the water level depth is
fluctuating and difficult to control.
3. The installation of float valve to limit the water depth is suitable for
the use of assembled equipment, and it is used in occasions with strict
water level requirements and limited space.
4. Circulating control of inlet and outlet water is suitable for occasions
with special requirements for water temperature and circulating water
source.
Precautions for the use of atomizer
1. The atomizer must be installed horizontally, and it is forbidden to
install it at an inclined angle, which will cause the partial atomization
sheet to be exposed to the surface of the water and dry and burn.
2. When the atomizer is working normally, please do not put your handson the spray cavity of the atomizer to prevent injury.
3. The atomizer must be in water to work normally. Please put it in the
water before turning on the power and make sure that the surface of the
atomizer is in a state of water to avoid damage to the atomizer.
4. When you stop using the atomizer, please disconnect the power first,
and then take out the atomizer from the water.
5. When using this atomizer, please select a power supply whose output
power is greater than the rated power of this product by more than 50w.
6. When multiple atomizers are used in the same container, care must be
taken to make the shells of the atomizers communicate with each other
to avoid the potential difference between the atomizers in the aqueous
solution and electrolysis of the ceramic sheets (atomizers) The shell itself
has positive electricity and there is a voltage difference between each
other) to prevent discharge corrosion during work.
7. The mist generated by the atomizer must be forcedly discharged by a
fan, and each group of atomizers reserves 350CM² of plane space to
avoid excessive water temperature and shorten the service life of the
atomizer.
8. Please do not damage the water level sensor switch during the
installation process, so as to avoid the failure of the water level switch
and cause the atomizer to lose control. Stop using the water level switch
if it is damaged, otherwise the atomizer sheet will burn dry and furtherdamage the atomizer. At this time, it must be repaired by professional
maintenance personnel before it can be used.
MODEL OKS-UAH150W     OKS-UAH180W   OKS-UAH250W   OKS-UAH300W   OKS-UAH350W
Rated Power         150W 180W 250W 300W   350W
Operating Voltage    DC36V   DC48V DC48V DC48V DC48V
Working current       4A 3.5A 5A  5.5A   6A
Stand-by current     0.02A 0.02A 0.02A 0.02A 0.02A
Atomization               2000ML/H 2500ML/H 4500ML/H 5000ML/H 5500ML/H
Working water temperature     5-50°C 5-50°C 5-50°C 5-50°C 5-50°C
Best water level    7-9CM 7-9CM 7-9CM 7-9CM 7-9CM
Turn on the water level      5.5CM  5.5CM  5.5CM  5.5CM  5.5CM
Turn off the water level
    
<5.5CM <5.5CM <5.5CM <5.5CM <5.5CM
Temperature control     55°C 55°C 55°C 55°C 55°C
Temperature control recovery    40°C  40°C  40°C  40°C  40°C
6 Head Fogger Maker Ultrasonic Mist Humidifier6 Head Fogger Maker Ultrasonic Mist Humidifier6 Head Fogger Maker Ultrasonic Mist Humidifier6 Head Fogger Maker Ultrasonic Mist Humidifier6 Head Fogger Maker Ultrasonic Mist Humidifier

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now